Back

Discovery Marine Waterproof Manual Call Point

Product code: 58100-975MAR

58100-975MAR - Discovery Marine Waterproof Manual Call Point
The Discovery Marine Manual Call Point has been approved for use in outdoor marine applications. A seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated, the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.
Full details
Operating Principles

The Discovery Marine Waterproof Manual Call Point (MCP) is based on the KAC conventional MCP range. It is electronically and mechanically compatible with previous Apollo call points based on KAC’s World Series product. The address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. If a MCP is activated, it interrupts the normal protocol to give a fast response. A single bi-coloured alarm LED is provided on the manual call point. This LED is controlled, independently of the call point, by the control panel and may be set to flash each time the call point is polled. The red LED is illuminated when the call point has been activated and sent into alarm. On the isolated versions an amber/yellow LED indicates a short-circuit on the loop wiring either side of the call point. Call points can be remotely tested from the panel by transmission of a single bit in the communications protocol. Call points respond by providing a value of 64 which corresponds to the alarm value. The panel should recognise this response as a test signal and should not raise a general alarm. For ease of installation Discovery Marine manual call points are supplied with clip-on terminal blocks and a connector which allows continuity testing before call points are commissioned.

Communication

Discovery

Maintenance & Service

Detectors should be maintained according to BS 5839-1 or other locally applicable code. Test equipment can be ordered from Apollo for testing smoke and heat detectors. Detectors should not be cleaned in the field except for careful removal of exterior dirt with a damp cloth. For cleaning and recalibration detectors should be returned to Apollo Fire Detectors or to the local distributor.

EMC Directive 2004/108/EC

The detector complies with the essential requirements of the EMC Directive 2004/108/EC, provided that it is used as described in this datasheet.

Construction products regulation 305/2011

The detector complies with the essential requirements of the Construction Products Regulation 305/2011.

Options

Discovery Marine manual call points are available with or without an isolator. Each version is available with a resettable element and a backbox for surface mounting as standard. If a glass option is required, spare glasses are available on request. To provide additional protection against accidental operation, a transparent hinged cover with a locking tag, part number 26729-152 is available, which can be fitted to the manual call point. Please note that the call point does not conform to EN54-11:2001 when this lid is fitted and secured with the locking tag.

Product Information

The Discovery Marine Manual Call Point has been approved for use in outdoor marine applications. A seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated, the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.

Key Features

‘Plug and Play’ terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element

General
Warranty10 year
Performance
Analogue value nominal16
Alarm level analogue value64
Electrical
Protocol voltage (min)5V
Protocol voltage (max)9V
Protocol voltage5 to 9V peak to peak
Power-up surge current 1mA
Maximum power-up time1 second
Quiescent current100μA
Quiescent current tested at24V dc
Supply voltage (min)17V dc
Supply voltage (max)28V dc
Supply voltage (Vmin-Vmax)17 to 28V dc
Terminal functions L2-L2 Line in & out negative
Terminal functions L1 in-L1 in Loop (isolated) negative
PolarityL1 & L2 are polarity sensitive
Alarm current (at 24 volts)4mA
Environmental
Humidity (min)0% RH
Humidity (max)95% RH
Humidity Noteno condensation or icing
Humidity0% to 95% (no condensation or icing)
Operating temperature (min)-4°F
Operating temperature (max)140°F
Operating temperature-4 to 140°F
IP rating Value IP24D
Conformance
Standards
  • EN 54-11
  • EN 54-17
Approvals
  • MED
  • DNV.GL
  • DNV.GL
  • ABS
Mechanical
Weight110g
ColourRed
Materials housing
  • Polycarbonate
  • ABS
Product length1.06in
Product width3.5in
Product depth3.66in
Detection principleOperation of a switch.
Key typeKAC Manal Call Point test & reset key
How to Order

Apollo is dedicated to ensuring that our customer service is aligned with your expectations. This includes making our order, service and delivery process a seamless and hassle-free experience.

Full details of our service standards can be downloaded here.

Existing customers

Please email your order to us at: ukorders@apollo-fire.com or tel: 023 9245 6530.

New customers

Please email your order to us at: sales@apollo-fire.com or tel: 023 9244 2700.

Oops…

Despite our best efforts, mistakes sometimes happen. Please contact us at: orderqueries@apollo-fire.com if you have any difficulties placing your order.

Please note…

Remember to quote your account number and purchase order number on any order correspondence.

All orders must be over £50.00 (excluding carriage). Any orders received under the minimum order value will be returned to sender for revision.