XP95 I.S. Manual Call Point (Red)

Product code: 55200-940APO

55200-940APO - XP95 I.S. Manual Call Point (Red)
The XP95® IS Manual Call Point has been designed to operate on a loop of intelligent fire detection devices and when activated interrupts the polling cycle for a very fast response. When activated, the intrinsically safe call point not only interrupts the polling cycle to indicate to the control panel that it has been operated, but also reports its address. Thus an alarm and its location can be reported in less than 0.2 seconds. Full details of the principles of operation and the electrical description are published in the XP95 Engineering Product Guide. XP95 IS manual call points have the same operating characteristics as the standard versions. They are available in two types of housing and in a number of versions. Designed specifically for use in atmospheres in which explosive mixtures are or may be present, certain design considerations must be observed. The standard red IS manual call point is EN54-11:2001 compliant and has a resettable element. The range uses an IP67 weatherproof polycarbonate housing and is available in colours other than red. A transparent hinged cover part no: 26729-152 is available for protection against accidental operation.
Full details
Brand Information

XP95 Intrinsically Safe (IS) detectors are a development of the well established analogue addressable XP95 range from Apollo. XP95 IS detectors feature all the benefits of the standard range, but are developed specifically for use in hazardous areas.

Electrical Considerations

The XP95 IS Manual Call Point is loop powered and operates at 14–22V DC.

Operating Principles

The address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. A red alarm LED is provided on the call point. This LED is controlled independently of the call point, by the control panel. This Manual Call Point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the Call Point. Once activated, the XP95 IS Manual Call Point can be reset by inserting the test key into the bottom of the unit until the key clicks into position. Remove the test key and push the front cover up until it clicks home

Mechanical Construction

The XP95 IS Manual Call Point mouldings are polycarbonate and ABS.

Communication

The XP95 IS Manual Call Point will operate only with control equipment using the Apollo XP95 digital protocol.

Backward Compatibility

Additional Information

Operating temperatures (ambient): –20°C to +70°C –20°C to +45°C (T5) –20°C to +60°C (T4)

Environmental Characteristics

The XP95 Manual Call Point, is designed for use only in an intrinsically safe system together with a protocol translator and a safety barrier. Details of system design can be found in Engineering Product Guide.

Technical Data

Additional Information 1

The protocol translator (part no. 55000–855 single channel, 55000–856 dual channel). ensures that the call point operates correctly while itself remaining transparent to the control panel.

Product Information

The XP95® IS Manual Call Point has been designed to operate on a loop of intelligent fire detection devices and when activated interrupts the polling cycle for a very fast response. When activated, the intrinsically safe call point not only interrupts the polling cycle to indicate to the control panel that it has been operated, but also reports its address. Thus an alarm and its location can be reported in less than 0.2 seconds. Full details of the principles of operation and the electrical description are published in the XP95 Engineering Product Guide. XP95 IS manual call points have the same operating characteristics as the standard versions. They are available in two types of housing and in a number of versions. Designed specifically for use in atmospheres in which explosive mixtures are or may be present, certain design considerations must be observed. The standard red IS manual call point is EN54-11:2001 compliant and has a resettable element. The range uses an IP67 weatherproof polycarbonate housing and is available in colours other than red. A transparent hinged cover part no: 26729-152 is available for protection against accidental operation.

Key Features

‘Plug and Play’ terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element

Search engine tags

55200940APO, 55200940, 55200-940, 55200 940

General
Warranty10 year
Electrical
Protocol voltage (min)5V
Protocol voltage (max)9V
Protocol voltage5 to 9V peak to peak
Power-up surge current 1μA
Maximum power-up timeCommercial
Quiescent current300μA
Supply voltage (min)14V dc
Supply voltage (max)22V dc
Supply voltage (Vmin-Vmax)14 to 22V dc
PolarityL1 & L2 are polarity sensitive
Environmental
Humidity (min)0% RH
Humidity (max)95% RH
Humidity Noteno condensation or icing
Humidity0% to 95% (no condensation or icing)
Operating temperature (min)20°C
Operating temperature (max)40°C
Operating temperature20 to 40°C
IP rating ValueIP67
Conformance
Approvals
  • BASEEFA
  • BOSEC
  • BRZ
  • CPR
  • IECEx
  • PESO (CCoE)
  • SBSC
  • VNIIPO
Mechanical
Weight240g
ColourRed
Materials housing
  • Polycarbonate
  • ABS
Product length97.5mm
Product width93mm
Product depth71mm
Detection principleOperation of a switch.
Key typeKAC Manal Call Point test & reset key
How to Order

Apollo is dedicated to ensuring that our customer service is aligned with your expectations. This includes making our order, service and delivery process a seamless and hassle-free experience.

Full details of our service standards can be downloaded here.

Existing customers

Please email your order to us at: ukorders@apollo-fire.com or tel: 023 9245 6530.

New customers

Please email your order to us at: sales@apollo-fire.com or tel: 023 9244 2700.

Oops…

Despite our best efforts, mistakes sometimes happen. Please contact us at: orderqueries@apollo-fire.com if you have any difficulties placing your order.

Please note…

Remember to quote your account number and purchase order number on any order correspondence.

All orders must be over £50.00 (excluding carriage). Any orders received under the minimum order value will be returned to sender for revision.