The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance and has unique features that benefit the installer and the end user.
The detectors have been carefully researched and developed by the Apollo design team and the range has undergone rigorous testing to ensure that it meets not only European and other standards but also the demands of today's high technology environments.
Ionisation Smoke Detector
Air in the dual sensing chambers is irradiated to produce ions that travel to the positive and negative electrodes, creating a current flow. As smoke enters the outer chamber, the flow drops and voltage increases. The voltage is measured and an analogue signal is converted to digital for transmission to the control equipment.
More information ...
Optical Smoke Detector
The XP95 optical detector uses an internal pulsing LED and a photo-diode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered and registered by the photo-diode. A signal is generated and transmitted digitally to the control equipment.
More information ...
Heat Detector
The XP95 heat detector has a low air-flow resistant case for good contact between the sensing thermistor and the surrounding air. Temperature is measured by a single thermistor network which gives a voltage output proportional to the external air temperature. The signal is processed and transmitted to the control equipment.
More information ...
Multisensor Detector
The XP95 multisensor detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value.
More information ...
Beam Detector
Beam detectors are designed to protect large open spaces such as atria, museums, churches and warehouses.
More information ...
Flame Detector
Flame detectors are effective in protecting areas where flaming fires may be expected.
More information ...
MiniDisc Remote Indicator
The MiniDisc Remote Indicator is a light-weight, compact indicator for use in fire protection systems.
More information ...
Intelligent Mounting Base
All detectors in the Discovery and XP95 range fit into the Intelligent Mounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.
More information ...
Intelligent Deep Base
The Intelligent Deep Base is a mounting base for Discovery and XP95 products which has an increased depth which allows for cables to be inserted into the side of the product.
More information ...
Intelligent Low Power Relay Base
The Intelligent Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers.
More information ...
NEW! Isolating Base
The new Isolating Base senses and detects short-circuit faults on Discovery and XP95 loops and spurs.
More information ...
Intelligent Heater Base
The Intelligent Heater Base is designed to be used in cold climates where environmental conditions could result in either icing or condensation affecting the operation of detectors.
More information ...
Intelligent Isolator
The Intelligent Isolator is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected.
More information ...
Intelligent Isolator Base
The Intelligent Isolator Base is unique and designed only to accept the Intelligent Isolator.
More information ...
Isolating Base
The Isolating Base senses and detects short-circuit faults on Discovery and XP95 loops and spurs.
More information ...
XP95 Manual Call Point
The XP95 Manual Call Point is compliant with EN54-11. The address of each call point is set at the commissioning stage by means of a seven segment DIL switch. The device features plug and play terminal connections and a resettable element.
More information ...