Intelligent Duct Smoke Detector

Product code: 53546-022APO

53546-022APO - Intelligent Duct Smoke Detector
The Intelligent Duct Smoke Detector provides early detection of smoke in the air moving through heating and ventilation (HVAC) ducts in commercial and industrial premises. Its purpose is to prevent the re-circulation of smoke from an area on fire to areas unaffected by the fire when used with a XP95 or Discovery detector
Full Details
Electrical Description

The duct smoke detector is supplied as a housing with a base fitted for either a conventional detector or an analogue addressable detector. The housing has provision for electrical connections depending on the type of detector fitted. For technical data on the detector head, please refer to the relevant product guide or PIN sheet.

Operation

The duct smoke detector is fitted to the side, the top or the bottom of the ventilation duct and has two tubes which extend into the air duct through holes in the duct wall. The perforated sampling tube which spans the duct is placed in the airflow upstream of the exhaust tube which causes a pressure differential in the duct detector. Air is sucked up the sampling tube, across the detector and exhausted back into the air duct. The duct smoke detector is designed to operate in ducts with a width of between 300mm and 3000mm. A sampling tube of 360mm, suitable for duct widths up to 540mm, is supplied as standard. Longer sampling tubes for wider ducts may be ordered separately: 150—750mm Part no 53541-170 750—1500mm Part no 53541-171 1500—3000mm Part no 53541-172 The tubes should be long enough to reach from one side of the duct to the other and it may be necessary to use a tube that is too long and cut it to slightly more than the duct width. Since the tube needs to be supported on both sides a hole should be cut in the opposite wall of the air duct to allow the tube to protrude slightly. The tube must be closed with the small red bung provided. The exhaust tube does not need to extend across the duct and is therefore supplied at a fixed length.

Application

To minimise the impact of air turbulence and stratification on performance a duct smoke detector should be located as far as possible downstream from any obstruction (ie, deflector plates, elbows, dampers, etc). In all situations confirmation of velocity and pressure differential within specifications is required. A uniform non-turbulent (laminar) airflow between 0.5 and 20m/s must be present in the air duct. The pressure differential between sampling (high pressure) and exhaust (low pressure) tubes should be between 0.025 and 3mbar. If installing the detector in the return air side of the air duct, locate it at a point where it will not be diluted with outside air. If possible, install duct smoke detectors upstream of air humidifiers and downstream of dehumidifiers. To minimise false alarms avoid mounting the detector in areas of extreme high or low temperatures, in areas of high humidity or in areas containing gases or high amounts of dust.

Device Addressing

If duct detector 53546-022 is used the address of the detector must be set before fitting the detector head. The address of the detector is set using the XPERT card. For address settings refer to the Installation Guide (PP2185).

Product Information

The Intelligent Duct Smoke Detector provides early detection of smoke in the air moving through heating and ventilation (HVAC) ducts in commercial and industrial premises. Its purpose is to prevent the re-circulation of smoke from an area on fire to areas unaffected by the fire when used with a XP95 or Discovery detector

General
Warranty10 year
How to Order

Apollo is dedicated to ensuring that our customer service is aligned with your expectations. This includes making our order, service and delivery process a seamless and hassle-free experience.

Full details of our service standards can be downloaded here.

Existing customers

Please email your order to us at: ukorders@apollo-fire.com or tel: 023 9245 6530.

New customers

Please email your order to us at: sales@apollo-fire.com or tel: 023 9244 2700.

Oops…

Despite our best efforts, mistakes sometimes happen. Please contact us at: orderqueries@apollo-fire.com if you have any difficulties placing your order.

Please note…

Remember to quote your account number and purchase order number on any order correspondence.

All orders must be over £50.00 (excluding carriage). Any orders received under the minimum order value will be returned to sender for revision.