The Conventional Base Mounted UV Flame Detector is designed to protect enclosed indoor areas where open flaming fires may be expected. The detector has a fast-acting response to flames up to 25m away and is equipped with a single UV sensor with a narrow spectral response in order to discriminate between flames and most spurious sources of radiation.
Full Details

Application Environments

Restaurants

Retail

Small to medium buildings

Brand Information

Series 65 incorporates well-proven sensing technologies, including an Integrated Circuit based on that used in XP95 analogue addressable detectors. The Series 65 range has a wide operating voltage of 9–33V and consists of ionisation, integrating ionisation and optical smoke detectors, four grades of heat detector and a range of bases.

Brand Features

Wide-operating voltage of 9–33 V DC Wide-operating and storage temperature of -20°C to +60°C Can be used on security systems Electrically and mechanically compatible with Series 60 Proven detection performance

Electrical Description

The detector signals an alarm state by switching an alarm latch on, increasing the current drawn from the supply from 550μA to a maximum of about 75mA. This fall in the impedance of the detector is recognized by the control panel as an alarm signal. The alarm current also illuminates the detector’s integral LEDs. A remote indicator connected between the L1 IN terminal and the –R terminal will have a voltage equal to the supply voltage less 1V across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33V DC and a minimum of 12V DC in normal operation. The supply may fall to 6V DC in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LEDs and any remote indicator, the supply to the detector should exceed 12V. To restore the detector to quiescent condition, ensuring all flames are extinguished, interrupt the electrical supply to the detector for a minimum of one second. Note: When using the detector the following must be avoided; outside viewing, UV lamps, electrical sparking, welding and sources of radiation, UV light sources, prolonged ambient temperatures above 60°C and obstructions to the field of view.

Operation

The detector is sensitive to ultraviolet radiation emitted by flames during combustion. Since it requires only UV radiation the Flame Detector responds even to stationary flames with no flicker like cigarette lighters and blue gas flames. The detector is set to respond to ultraviolet radiation (185 to 260nm) emitted by almost all flames, including those invisible to the naked eye, e.g. hydrogen fires. The detector has a single UV sensor with a narrow spectral response in order to discriminate between flames and most spurious sources of radiation and is designed for internal fully enclosed areas. Caution: The detector will also detect electrical discharges from lightning or arc welding.

Application

UV flame detectors are designed for use in enclosed spaces and require a clear line of sight within the area to be protected. They are unaffected by draughts or convection currents. They are fast reacting and respond to a flame more than 25m away.

Additional Information

Installation note: If fitting to an XP95 Zone Monitor do not fit more than one device per zone. If fitting to a conventional control panel, please verify the quanity per zone with the chosen panel manufacturer. The field of view of the flame detector is shown in Fig. 1 (refer to datasheet PP2399). This also provides information on the size of fire detectable at various distances. The Flame Detectors can also be ceiling mounted, positioned above the anticipated flame source or at the centre of the area to be protected, perpendicular to the floor below. If the detector cannot see the whole of the area to be protected, one or more additional detectors may be required. Refer to the angle of view diagram Fig. 2 (refer to datasheet PP2399) to establish the detector performance. The area of detection is dependent on the detectors height above the likely source of flame. The detector has a 90° conical field of view or 45° either side of the viewing axis centre line. The maximum ceiling height is 20m. If the detector is perpendicular to floor and at a height of 10m then the detector will view a circular floor area below with a 10m radius (20m diameter circle).

Product Information

The Conventional Base Mounted UV Flame Detector is designed to protect enclosed indoor areas where open flaming fires may be expected. The detector has a fast-acting response to flames up to 25m away and is equipped with a single UV sensor with a narrow spectral response in order to discriminate between flames and most spurious sources of radiation.

Key Features

Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which fits into Series 65 bases Zone-powered To be used with either Series 65 or Orbis Systems

General
Applications
  • Restaurants
  • Retail
  • Small to medium buildings
Warranty10 year
Electrical
Quiescent current550μA
Environmental
Humidity (min)0% RH
Humidity (max)95% RH
Humidity Noteno condensation or icing
Humidity0% to 95% (no condensation or icing)
Operating temperature (min)-40°C
Operating temperature (max)70°C
Operating temperature-40 to 70°C
Storage temperature (min)95°C
Storage temperature (max)-40°C
Storage temperature95 to -40°C
Conformance
StandardsEN 54-10
Approvals
  • CPR
  • LPCB
Mechanical
ColourWhite
How to Order

Apollo is dedicated to ensuring that our customer service is aligned with your expectations. This includes making our order, service and delivery process a seamless and hassle-free experience.

Full details of our service standards can be downloaded here.

Existing customers

Please email your order to us at: ukorders@apollo-fire.com or tel: 023 9245 6530.

New customers

Please email your order to us at: sales@apollo-fire.com or tel: 023 9244 2700.

Oops…

Despite our best efforts, mistakes sometimes happen. Please contact us at: orderqueries@apollo-fire.com if you have any difficulties placing your order.

Please note…

Remember to quote your account number and purchase order number on any order correspondence.

All orders must be over £50.00 (excluding carriage). Any orders received under the minimum order value will be returned to sender for revision.