Xpander Diversity Loop Interface Unit

Product code: XPA-IN-14050-APO

XPA-IN-14050-APO - Xpander Diversity Loop Interface Unit
The XPander Diversity Loop Interface Unit can monitor up to 31 XPander devices and report each device’s status to an intelligent fire control panel.
Full Details
Brand Information

XPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal, pre-alarm, fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery, detector contaminated, detector tamper and low signal strength fault conditions.

Brand Features

modern styling loop-powered interface operating on 868MHz wireless addresses seen by control panel as normal addresses radio base with wireless circuitry and battery compartment chamber designed to inhibit dirt penetration and thus reduce false alarms automatic drift compensation with DirtAlert™ warning algorithms for transient alarm rejection FasTest™ reduces time taken to test detectors remote test facility 3-5 years battery life

Operation

The XPander Diversity Interface is connected to the loop and provides communications from the control panel to the wireless devices and vice versa. Features of the XPander Diversity Loop Interface are: • It is powered from the loop. • A maximum of five interfaces can be connected to a loop. • Up to 31 radio devices can be logged on to each interface. The current drawn from the Interface should be taken into consideration when calculating the total load of a loop. The XPander Diversity Interface has an integral LCD display which gives information on the state of the wireless detectors. The Diversity Interface transmits and receives signals via the integral Diversity Aerials which require no adjustment or maintenance.

Application

The XPander interface aerial must be installed at least 400mm away from any metal object. The recommended minimum distance to any electrical equipment is 2 metres in all three dimensions.

Device Addressing

An 8-segment DIL switch is provided for the address of the Interface to be set. When polled by the control panel, the XPander Interface returns a pre-set analogue value of 16 in normal condition.

Communication

Radio Communications Fire detection systems are life-saving systems and must, therefore, be highly reliable in use. Radio communications have been developed to a point where high reliability can be guaranteed, provided that the rules for the design of radio systems and installation are carefully observed. Radio communication technology in the detection has matured to the point where a standard has been drawn up as part of the EN54 family of standards for components of a fire detection system. The standard is EN54 Part 25. Frequency The frequency used by XPander is 868MHz which is the harmonised European radio frequency.

Maintenance & Service

Detectors should be checked regularly at the intervals indicated by the locally applicable code of practice. Apollo recommends that the detectors be checked at least once a year. If detectors appear not to be functioning correctly they should be returned to Apollo for testing. If detectors are externally dirty they can be cleaned carefully with a damp cloth using a small amount of industrial alcohol.

Additional Information

Devices in the XPander range are powered by batteries. There are two battery packs, with current being drawn alternatively from each. It is essential that the state of the batteries be known.

Product Information

The XPander Diversity Loop Interface Unit can monitor up to 31 XPander devices and report each device’s status to an intelligent fire control panel.

Key Features

Connects up to 31 XPander devices to an Apollo Addressable loop Translates radio signals from XPander detectors to the fire control panel Built-in loop isolator Loop-powered Diversity aerial design for improved signal integrity

General
Warranty10 year
Environmental
Humidity (min)0% RH
Humidity (max)95% RH
Humidity Noteno condensation or icing
Humidity0% to 95% (no condensation or icing)
Operating temperature (min)-10°C
Operating temperature (max)55°C
Operating temperature-10 to 55°C
Conformance
Standards
  • EN 54-17
  • EN 54-18
  • EN 54-25
ApprovalsCPR
Mechanical
Weight950g
ColourWhite
Materials housingABS
Product length205mm
Product width270mm
Product depth85mm
Information icon
Please Log in or register for unlocked and editable PDFs, BIM Objects and Product Images.
Sales Literatures
Data Sheets
Product Guides
Installation Guides
Information icon
Please Log in or register for unlocked and editable PDFs, BIM Objects and Product Images.
Certification Documents
Declaration of Performance
How to Order

Apollo is dedicated to ensuring that our customer service is aligned with your expectations. This includes making our order, service and delivery process a seamless and hassle-free experience.

Full details of our service standards can be downloaded here.

Existing customers

Please email your order to us at: ukorders@apollo-fire.com or tel: 023 9245 6530.

New customers

Please email your order to us at: sales@apollo-fire.com or tel: 023 9244 2700.

Oops…

Despite our best efforts, mistakes sometimes happen. Please contact us at: orderqueries@apollo-fire.com if you have any difficulties placing your order.

Please note…

Remember to quote your account number and purchase order number on any order correspondence.

All orders must be over £50.00 (excluding carriage). Any orders received under the minimum order value will be returned to sender for revision.